Main Menu:
What is a Sentinel Lymph Node?
In the breast, a network of
lymphatic vessels drain fluid and cells to the bean-shaped lymph nodes in the axilla
(armpit). The sentinel node is the very first lymph node(s) to receive
drainage from a cancer-containing area of the breast. What is Sentinel Lymph Node Biopsy?When breast cancer is diagnosed,
women (and men) must often undergo axillary lymph node
dissection (i.e., removal of underarm nodes) to check for the spread of cancer. This
process is part of staging the cancer.
Unfortunately, the removal of these lymph nodes can lead to lymphedema (chronic
swelling) of the arm in a certain percentage-- about 10-20%--of cases. How is Sentinel Lymph Node Biopsy Performed?Before going to the operating room, the surgeon injects a small dose of a low-level radioactive tracer called technetium-99 into the breast in the region of the patients tumor. Technetium-99 contains less radiation than a standard x-ray, CT scan or bone scan and is a relatively safe substance. A blue dye is also injected to help visually track the location of the sentinel node during surgery. The surgeon then uses a hand held counter to detect the radioactive tracer and locate the sentinel node. Sometimes, nuclear medicine images (also known as lymphoscintigraphy) of the lymphatic system will be obtained after injecting the technetium-99 before surgery. Since the uptake of the technetium-99 by cancerous lymph nodes is sometimes different than the uptake by normal lymph nodes, these nuclear medicine images may also help show which lymph nodes are cancerous. Next, the surgeon will wait for the technetium-99 and dye to travel from the tumor region to the sentinel lymph node(s), just as cancer cells might spread. Depending on the protocol followed, the surgeon usually waits between 45 minutes to 8 hours after injection before bringing a patient to the operating room for the biopsy. At some point during the procedure, a small amount of blue dye will also be injected into the breast tissue near the area of the tumor. Once the technetium-99 tracer and dye have reached the nodes, the surgeon will scan the area with an electric, hand-held gamma ray counter (called a Geiger counter) to detect the radioactive technetium-99. The gamma ray counter is attached to a small probe which the surgeon traces over the axilla to locate the sentinel node(s). When the radioactive agent is found, the gamma ray counter will emit an audible tone, revealing the exact location of the sentinel node(s). Once the area has been pinpointed, the surgeon will make a small incision (usually one-half inch) and remove the sentinel node(s) for a pathologist to examine under a microscope. The blue dye provides additional visual confirmation of the sentinel nodes location during surgical removal. Several clinical trials have revealed that in the vast majority of cases, if the sentinel node does not contain cancer, then the cancer has not spread past the breast. Sentinel node biopsy does not usually require the placement of a fluid drainage tube (common in axillary node dissection). Why is Sentinel Lymph Node Biopsy Performed?
Sentinel lymph node biopsy may help in
determining which patients can avoid axillary node dissection and the removal of 10 to 30
lymph nodes. Most patients have only one to three sentinel lymph nodes under the
arm. Thus, an average of only two lymph nodes are removed in each patient with a
sentinel node biopsy. This, in turn, may reduce post-operative complications.
A standard axillary node dissection, removal of the
underarm lymph nodes, usually requires a larger four to six inch incision and a longer
recovery period than a sentinel node biopsy.
In a recent study published in The New England Journal of Medicine, 443 patients at 11 medical centers across the United States underwent sentinel node biopsies. Researchers discovered that if the gamma ray counter detected the radioactive agent (technetium-99) in the patients, then the sentinel node biopsy was 97% accurate in pinpointing all cancerous lymph nodes. However, the study was not completely successful. The gamma ray counter missed cancerous nodes in 13 of the 114 women whose cancer had spread past the breast. In an upcoming study, researchers at the National Cancer Institute will compare sentinel node biopsy to the standard method of lymph node removal (axillary node dissection) on 4000 women to determine which procedure is superior. |
||||||
Imaginis.com suscribes to the HONcode principles of the Health on the Net Foundation.
Copyright 1997-2009 Imaginis Corporation. All rights reserved. Imaginis® is a registered service mark of Imaginis Corporation, a health services company. All other trademarks and copyrights are property of their respective owners. Note: Use of this online service is subject to the disclaimer and the terms and conditions contained herein. Information found within the Imaginis.com website or in other sites linked to from Imaginis.com is provided for educational purposes only and is not intended to be used as a substitute for diagnosis and treatment by a medical doctor. Imaginis does not endorse and has no responsibility for the content of any other sites listed on Imaginis.com, and provides links and references merely as a convenience to its users. Seek immediate medical attention if your condition is urgent. Imaginis - The Breast Cancer Resource